20
Connection
6.11 I/O signals
This section explains about input signals and output signals.
6.11.1 I/O signals list
Input signals
Terminal name Signal name Description
DIN0 START/STOP This signal is used to rotate the motor or decelerate to stop it.
3-Wire modeDIN1 RUN/BRAKE This signal is used to rotate the motor or stop it instantaneously.
DIN2 FWD/REV This signal is used to select the motor rotation direction.
DIN3 M0
These signal are used to select the operation data number.
DIN4 M1
DIN5 ALM-RST This signal is used to reset the alarm generated presently.
Signals
possible to
change the
assignment
FWD
*
This signal is used to rotate the motor in the forward direction.
2-Wire modeREV
*
This signal is used to rotate the motor in the reverse direction.
STOP-MODE
*
This signal is used to select how to stop the motor.
M2 This signal is used to select the operation data number.
TL This signal is used to switch whether to enable or disable the torque limiting function.
INFO-CLR This signal is used to reset the information generated presently.
HMI This signal is used to release the function limitation of the
MEXE02
.
EXT-ERROR This signal is used to stop the motor forcibly by the external signal.
H-FREE
This is the input signal that can be used when the load holding function is enabled.
If the H-FREE input is turned ON when the stopped motor shaft is electrically held by
the load holding function, the motor shaft can be rotated by an external force (free-run
state).
*
This is a signal to switch using a parameter.