13 Information
The driver is equipped with a function to generate information output before an alarm is generated.
This function can be utilized for periodic maintenance of equipment by setting a suitable value in the parameter of each
information.
Set and check using the information monitor of the
MEXE02
.
Status when information is generated
z
Information bit output
If information is generated, a bit output (INFO-** output) of the corresponding information is turned ON.
The bit output can be checked using the internal I/O monitor and waveform monitor of the
MEXE02
.
z
INFO output
If any of information is generated, the INFO output will be turned ON.
z
LED indicator
If information is generated, the PWR/ALM LED will blink in orange.
z
Motor operation
The motor continues to operate during information unlike in the case of an alarm.
z
Parameter
Conditions of the cause of generation for some information can be adjusted by parameter setting.
Each information has a corresponding "INFO action" parameter. If the parameter is set to "Not reected (Only bit output
turned ON)," only the bit output of information is turned ON, and the INFO output and LED are not changed.
Also, by setting the "Information auto clear" parameter, you can select whether the INFO output or the bit output of the
corresponding information is automatically turned OFF when information is cleared.
13.1 Information history
Up to 16 generated information are saved in the RAM in order of the latest to oldest.
The information items stored as information history are the information code, generation time, and contents of
information.
The stored information history can be checked using the
MEXE02
.
Note
Information history will be cleared if the power supply of the driver is turned OFF.