9.3 Operation data extension setting
A: Update immediately, B: Update after operation stop, C: Update after executing conguration
Parameter name Description Setting range Factory setting Update
Speed upper limit
Sets the upper limit value of the speed
command.
80 to 3150 [r/min] 3150
BSpeed lower limit
Sets the lower limit value of the speed
command.
80 to 3150 [r/min] 80
Torque limiting
maximum value
Sets the upper limit value of torque
limiting command.
0 to 200 [%] 200
External setting method
Selects the function of the external
setting device.
External analog setting device,
PWM signal input
External analog
setting device
C
External analog
operation speed
command gain
Sets the speed command per 1 VDC of
the input voltage by the external analog
setting device.
0 to 3150 [r/min/V] 640
A
External analog
operation speed
command oset
Sets the oset of the speed command by
the external analog setting device.
−1500 to +1500 [r/min] 0
External analog torque
limiting gain
Sets the torque limiting value per 1 VDC
of the input voltage by the external
analog setting device.
0 to 200 [%/V] 43
External analog torque
limiting oset
Sets the oset of the torque limiting by
the external analog setting device.
-
100 to +100 [%] 0
9.3.1 Limiting the setting range of the rotation speed
"Speed upper limit" parameter and "Speed lower limit" parameter
The setting range of the rotation speed is set to 80 to 3150 r/min at the time of shipment. This setting range can be
changed to limit.
Setting range of rotation speed
r/min
r/min
[Example]
When limiting the speed range
by setting to the speed upper
limit to 2000 r/min and the
speed lower limit to 200 r/min
80
3150
200 2000
Factory setting
z
Speed upper limit
Set the upper limit value of the rotation speed with the "Speed upper limit" parameter.
If the rotation speed exceeding the "Speed upper limit" is already set in the operation data, the rotation speed is limited
to the value set in the "Speed upper limit" parameter.
z
Speed lower limit
Set the lower limit value of the rotation speed with the "Speed lower limit" parameter.
If the rotation speed below the "Speed lower limit" is already set in the operation data, the rotation speed is limited to
the value set in the "Speed lower limit" parameter.
When the operating rotation speed is limited to the value set in the "Speed upper limit" parameter or "Speed
lower limit" parameter, the rotation speed setting error (INFO-SPD-DE) information is generated.