66
Specications
14.2 General specications
Operating environment
Ambient temperature Driver: 0 to +50 °C [+32 to +122 °F] (non-freezing)
Ambient humidity 85% or less (non-condensing)
Altitude Up to 1000 m (3300 ft.) above sea level
Surrounding atmosphere
No corrosive gas, dust, water or oil.
Cannot be used in radioactive materials, magnetic eld, vacuum or other
special environment.
(For details about installation locations, refer to p.9.)
Vibration
Not subject to continuous vibrations or excessive impact.
In conformance with JIS C 60068-2-6 "Sine-wave vibration test method"
Frequency range: 10 to 55 Hz Pulsating amplitude: 0.15 mm (0.006 in.)
Sweep direction: 3 directions (X, Y, Z) Number of sweeps: 20 times
Storage environment
Shipping environment
Ambient temperature Driver:
-
25 to +70 °C [
-
13 to +158 °F] (non-freezing)
Ambient humidity 85% or less (non-condensing)
Altitude Up to 3000 m (10000 ft.) above sea level
Surrounding atmosphere
No corrosive gas, dust, water or oil.
Cannot be used in radioactive materials, magnetic eld, vacuum or other
special environment.
Degree of protection IP00
14.3 Dimension
Mass: 46 g (1.62 oz.) [Unit: mm (in.)]
[50 (1.97)]
Installation of motor cabl
e
34.5±0.2
(1.358±0.008)
6 (0.236)
55 (2.17) max.
4 (0.157)63±0.2 (2.480±0.008)
72 (2.83) max.
3.5 (0.138)
64±0.2 (2.520±0.008)
3.5 (0.138)
27 (1.06) max.
ϕ
3.5 (
ϕ
0.138) Thru
22±0.2
0.866
±0.008
( )

Table of Contents