43
Settings of MEXE02
9.2 Parameter list
Parameter name Setting range Factory setting Update
Reference
page
Operation data extension setting
Speed upper limit 80 to 3150 [r/min] 3150
B
P.46
Speed lower limit 80 to 3150 [r/min] 80
Torque limiting maximum
value
0 to 200 [%] 200
External setting method
External analog setting device,
PWM signal input
External analog setting device C
External analog operation
speed command gain
0 to 3150 [r/min/V] 640
A
External analog operation
speed command oset
−1500 to +1500 [r/min] 0
External analog torque
limiting gain
0 to 200 [%/V] 43
External analog torque
limiting oset
-
100 to +100 [%] 0
Operation and I/O action
Impact softening lter
No lter,
Filter 1,
Filter 2
No lter B
P.49
Deceleration mode selection
Deceleration stop 1,
Deceleration stop 2,
Deceleration stop 3
Deceleration stop 1
C
Motor rotation direction
+=CCW
+=CW
+=CW
Operation input mode
selection
2-Wire mode,
3-Wire mode
3-Wire mode
VA detection width 1 to 400 [r/min] 200 A
Load holding function
selection
Disable
Enable
Disable C
Load holding torque limiting
setting value
-
1 to 50 [%]
-1
(Operation data is followed)
A
Alarm and information settings
Overload alarm detection
time
0.1 to 10.0 [s] 10.0 A
P.53
Prevention of operation at
power-on alarm
Disable
Enable
Enable C
Information auto clear
Disable
Enable
Enable
A
Driver temperature
information
40 to 85 [°C] 85
Overvoltage information 18.0 to 38.0 [VDC] 38.0
Undervoltage information 18.0 to 38.0 [VDC] 18.0
Load information
0 (disable),
1 to 200 [%]
0
Speed information
0 (disable),
1 to 5200 [r/min]
0
Tripmeter information
0.0 (disable),
0.1 to 99999999.9 [kRev]
0.0
Odometer information
0.0 (disable),
0.1 to 99999999.9 [kRev]
0.0
Main power supply time
information
0 (disable),
1 to 999,999,999 [min]
0
Main power supply count
information
0 (disable),
1 to 999,999,999 [times]
0
INFO action (Driver
temperature information
(INFO-DRVTMP))
INFO action is not applied, INFO
action is applied
INFO action is appliedINFO action (Overvoltage
information (INFO-OVOLT))
INFO action (Undervoltage
information (INFO-UVOLT))

Table of Contents