44
Settings of MEXE02
Parameter name Setting range Factory setting Update
Reference
page
Alarm and information settings
INFO action (Load
information (INFO-LOAD))
INFO action is not applied, INFO
action is applied
INFO action is applied A P.53
INFO action (Speed
information (INFO-SPD))
INFO action (Operation data
setting error information
(INFO-SET-E))
INFO action (Operation
prohibited information
(INFO-DRV))
INFO action (Tripmeter
information (INFO-TRIP))
INFO action (Odometer
information (INFO-ODO))
INFO action (Torque
limiting value setting error
information (INFO-TRQ-DE))
INFO action (Rotation speed
setting information (INFO-
SPD-DE))
INFO action (Main power
supply time information
(INFO-PTIME))
INFO action (Main power
supply count information
(INFO-PCOUNT))
INFO action (Operation start
limiting mode information
(INFO-DSLMTD))
INFO action (I/O test mode
information (INFO-IOTEST))
INFO action (Conguration
request information (INFO-
CFG))
INFO action (Power cycling
request information (INFO-
RBT))
Monitor setting
Driver user name Up to 16 characters
A P.54
Speed reduction ratio 100 to 9999 100
Speed reduction ratio digit
setting
×1,
×0.1,
×0.01
×0.01
Speed increasing ratio 1.00 to 2.00 1.00
I/O function selection
DIN0 input function selection
Not used, ALM-RST, INFO-CLR,
HMI, TL, EXT-ERROR,
FWD (START/STOP)
*
,
REV (RUN/BRAKE)
*
, M0, M1, M2,
STOP-MODE (FWD/REV)
*
,
H-FREE
FWD (START/STOP)
*
C P.55
DIN1 input function selection REV (RUN/BRAKE)
*
DIN2 input function selection STOP-MODE (FWD/REV)
*
DIN3 input function selection M0
DIN4 input function selection M1
DIN5 input function selection ALM-RST
DIN0 logic level setting
Not invert, Invert
Not invert
DIN1 logic level setting Not invert
DIN2 logic level setting Not invert
DIN3 logic level setting Not invert
DIN4 logic level setting Not invert
DIN5 logic level setting Not invert
*
If the 3-wire input mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( )
will be applied.