48
Settings of MEXE02
9.3.4 Adjusting gain and oset for rotation speed command
If gain and oset are adjusted when the rotation speed is set using the external DC voltage or external potentiometer,
the slope of the speed command can be changed, and the speed can nely be adjusted.
Note
The rotation speed corresponding to the voltage value varies depending on the product.
z
Gain adjustment and oset adjustment for rotation speed
Adjust using the following parameters.
0
ternal analog operation
speed command gain
Speed lower limit
Speed upper limit
15
Ex
speed command oset
=
Maximum value
of setting voltage
External analog operation
speed command gain∗
*
If the motor does not reach the speed upper limit
when the setting voltage is the maximum value,
increase the value in the "External analog operation
speed command gain" parameter.
z
Setting example: When the motor is operated linearly in a state where the maximum rotation speed is set to
2000 r/min
Set the "Speed upper limit" parameter to 2000 rst, and set the "External analog operation speed command gain"
parameter to 400.
0
3150
5
Setting voltage [VDC]
Motor output shaft speed (r/min)
0
3150
2000
5
Setting voltage [VDC]
0
3150
2000
5
Setting voltage [VDC
or output shaf
or output shaf
Refer to "How to adjust the speed dierence" on p.36 for how to use the "Analog operation speed command oset" parameter.