64
Information
Information
Information bit
output signal
Cause Condition to reset and clear
Torque limiting value
setting error
INFO-TRQ-DE
A value exceeding the "Torque limiting
maximum value" parameter was set
in the torque limiting value of the
operation data.
A value lower than the "Torque
limiting maximum value" parameter
was set again in the torque limiting
value of the operation data.
A value exceeding the torque limiting
value of the operation data was
set again in the "Torque limiting
maximum value" parameter.
Rotation speed setting
error
INFO-SPD-DE
A value outside a range of the "Speed
upper limit" parameter and "Speed lower
limit" parameter was set in the rotation
speed of the operation data.
A value in a range of the "Speed
upper limit" parameter and "Speed
lower limit" parameter was set again
in the rotation speed of the operation
data.
A value was set again in the "Speed
upper limit" parameter or/and "Speed
lower limit" parameter so that the
rotation speed of the operation data
was in a range of the parameters.
Main power supply
time
INFO-PTIME
A time period having supplied the power
to the main power supply of the driver
increased to the setting value of the
"Main power supply time information"
parameter or more.
The "Main power supply time
information" parameter was set again,
and the time period having supplied
the power to the main power supply of
the driver dropped below the setting
value of the "Main power supply time
information" parameter.
Main power supply
count
INFO-PCOUNT
The number of times for turning on
the main power supply of the driver
increased to the setting value of the
"Main power supply count information"
parameter or more.
The "Main power supply count
information" parameter was set again,
and the number of times for turning
on the main power supply of the driver
dropped below the setting value of the
"Main power supply count information"
parameter.
Operation start limit
mode
INFO-DSLMTD
Conguration was executed.
"Teaching/remote operation" was
executed using the
MEXE02
.
Writing was performed using the
MEXE02
.
"Restored to the factory setting" was
executed using the
MEXE02
.
Conguration was complete.
"Teaching/remote operation" was
released.
"Restored to the factory setting" was
complete.
I/O test mode INFO-IOTEST
"I/O test" was executed using the
MEXE02
.
Conguration was executed.
"I/O test" was released.
Conguration was complete.
Conguration request INFO-CFG
The parameter change required
conguration was executed.
Conguration was executed.
Power cycling request INFO-RBT
The parameter change required to turn
on the driver power again was executed.
Turning on the driver power again was
executed.