EasyManua.ls Logo

Orisec CT-10 - Add;Delete Users

Default Icon
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41
Add/Delete Users
This section covers programming of the system users.
User 01 is the “Master” user which has a default code of 5678.
Users 02 onwards can be programmed to any user type and default to “Not in Use”.
User Codes
Each user must be assigned an access code to operate the system. Access codes may be 4, 5
or 6 digits in length. This option allows each user to be assigned an access code.
If a code is already existent within the system or the code length is incorrect (i.e. 0-3
digits) the system will reject the code and leave the code field blank.
User Type
The user type defines the level of access the user has when operating the security system. This
option allows the selected user type to be assigned. User 00 and User 01 types cannot be
changed.
No
Type & description
0
Not in Use
The selected user is not in use.
1
Engineer
The Engineer type can only be assigned by the installation company.
2
Technician
The Technician type can only be assigned by the installation company.
3
Master
A Master user can access all options within the user menu and program new users.
4
Manager
A Manager user can access all options within the user menu except the 'Change settings'
menu.
5
Standard
A Standard user can access the following options from the user menu: Full arm system’, Part
arm, ’Area full arm’, Change my code’ and ‘Reset alarms’.
6
Local Standard
A Local Standard user has the same rights as a Standard User. However, a Local Standard
user can only arm and disarm areas that are assigned to both their code and keypad. For
example, if the user is assigned to all areas, and keypad 1 is assigned to area 1, then the user
can only arm and disarm area 1 from keypad 1.
7
Duress
A Duress user operates the same as a standard user, however, on entering the access code a
silent duress alarm is generated and, if programmed, the event is signalled to the alarm
receiving centre.
8
Arm Only
An Arm Only user can only access the arming options within the user menu.

Other manuals for Orisec CT-10