Installation and Operation Manual of the EUROMATIK.net Page 11 (40)
Connecting the EUROMATIK drive for the 6-way valve
The 6-core connecting cable with plug provided must be used for connecting the servo
drive. The wires should not be interchanged when connecting the cable to the control
device!
This cable must be ordered out separately with the designation "EUROMATIK
connecting cable" and the item no. 202.160.0420.
For the backwashing and rinsing, you can use either plunger valves or a EUROTMATIK
drive for a 6-way valve.
Fault indication output
A signal for external fault indication can be tapped at the terminals 11 and 12.
The response of this output can be configured in the service menu under "Alarm settings".
Connecting plunger valves for backwashing
A 230 V plunger valve can be connected to the terminals U10 and N for backwashing.
A 230 V plunger valve can be connected to the terminals U11 and N for rinsing.
Both valves are controlled by the internal backwashing controller.
During backwashing, the backwashing pump (terminals 8 and 9) is also activated.
The heater and dosing equipment are blocked during the backwashing and rinsing
operations.
For backwashing and rinsing, you can use either plunger valves or a EUROTMATIK drive for a 6-way valve.
Connecting floor drainage motorized valve
If the stock of water in the collection tank is inadequate, you have the option of taking the
water directly from the swimming pool through the floor drain.
A motorized valve that gives access to the floor drainage system can be connected to the
terminals U7 and U8.
During the backwashing and rinsing operation, this valve is opened, and otherwise it is
closed.
The contact can be used to drive a 230 V 1A load.
Optionally, this valve can also be used to drain off the overflow gutter in the ECO mode of
operation.