Installation and Operation Manual of the EUROMATIK.net Page 9 (40)
If there is no air heat pump present, the potential-free contact between the terminals between 13 and 14 can
be used for controlling the boiler of the calorific heater.
If a swimming pool air heat pump is available, this contact is used to switch the heat pump on.
Connecting the dosing equipment
An additional 230 V device (e.g. dosing equipment or UV sterilization system) can be
connected that is switched on simultaneously with the filter pump in the filtration mode.
A potential-free contact is available in the control device between the terminals 15 and
16. This can be used to control the dosing equipment. It is closed during the filtration
operation.
The contact can be used to drive a maximum load of 230 V 4 A.
Connecting the attraction output
An additional 230 V device (e.g. underwater floodlight) can be connected to the terminal U4
that can be switched on and off as desired with a button on the front panel (or in the external
control panel).
The icon for this button can be selected in the menu.
Connecting a Grando swimming pool cover
A swimming pool cover of Grando make can be
connected to the terminals 17-24.
This plan represents only a connection example. The
applicability of this plan for the actually used version
of the Cover control must be assessed against the
operating instructions for the cover manufacturer.
The contacts can be used to drive a maximum load
of 230 V 1 A.
Connecting a Bieri swimming pool cover
A swimming pool cover of Bieri make can be connected to the terminals 17-24.
This plan represents only a connection example. The applicability of this plan
for the actually used version of the Cover control must be assessed against the
operating instructions for the cover manufacturer.
The contacts can be used to drive a maximum load of 230 V 1 A.