Installation and Operation Manual of the EUROMATIK.net Page 8 (40)
Mains connections when using a Zodiac FloPro VS pump
A Zodiac FloPro VS pump can be controlled directly by the
EUROMATIK.net.
Jumpers must be inserted between the terminals 5 and C and
between 7 and 8.
A jumper must be inserted between the two "WSK" terminals.
The power supply for the pump must be fed independently from
the mains supply and cannot be provided by the EUROMATIK.net.
The operation manual of the pump must necessarily be observed
and followed!
At the pump, the speed controller must be
connected to the designated terminals on the back of the user interface. The speeds required
for ECO mode (level 1), normal mode (level 2) and backwash mode (level 3) must be
assigned to speed levels 1 to 3.
Connecting a backwash pump
A backwash pump or a blower can be connected to the terminals 8 and 9 if no
speed-controlled filter pump is used.
The potential-free contact between the terminals 8 and 9 is closed during the
backwash operation.
The contact can be used to drive a 230 V 3A load. If pumps with larger values
of power are used, an additional terminal box (Item no.: 3002400000)
must be connected in between.
Connection of an additional filter pump (ECO pump)
An additional pump with lower power rating can be connected for the ECO
mode, if no speed-controlled filter pump is used.
The potential-free contact between the terminals 5 and 6 is closed while the
ECO pump is being controlled.
The contact can be used to drive a 230 V 3A load. If pumps with larger values
of power are used, an additional terminal box (Item no.: 3002400000)
must be connected in between.
Connecting the heater
The circulation pump of the heater can be connected to the terminals
U2 and N.
For the operation of the solar heater, a 230 V solar servo drive
can be connected to the U5 and U6 terminals. In the solar mode of
operation, the U5 terminal has the mains voltage and the U6 terminal is
at zero potential. If the solar heater is not controlled, the U5 terminal is
at zero potential and the U6 terminal has the mains voltage.