Installation and Operation Manual of the EUROMATIK.net Page 30 (40)
Configuration of the filter pump
Selecting the type of pump
During commissioning the type of filter pump must
be selected. The following options are available:
A three-phase filter pump
A single-phase filter pump
2 pumps, filter pump three-phase, ECO
pump single-phase
2 pumps, both single-phase
A variable speed pump
If a variable speed pump is used, the exact type
must be defined using the button "Choice of
variable pump".
Adjusting the motor protection
You can set the current level for triggering motor
protection by pressing the "Motor overload
protection" button. Finally, press the "OK" button to
save the setting.
The current consumption of the pump is displayed on the
"INFO" page.
The motor protection feature can be used only if
400 V / 50 Hz or 230 V / 50 Hz filter pumps are
used that are connected to the terminals U1/V1/W1.
If a pump with a variable speed pump is selected
during the configuration, the motor protection
feature is not active.
Setting the start-up time of the pump
You can set the delay time that elapses before the
flow monitor is sensed after starting the filter pump
by pressing the "Pump starting time" button. Finally,
press the "OK" button to save the setting.
Pump capacity for solar heating
In this line you can select, at which power the filter
pump should run during operation of the solar
heating.
Configuration of the heating systems
Selecting the heating systems
During commissioning you have to define which
heating systems are present in the installation.
For the operation of a solar absorber system, a
solar temperature sensor must be connected to the
terminals 53 and 54.
For the operation of an air heat pump, an outdoor
air temperature sensor must be connected to the
terminals 55 and 56.
Temperature limit
You can set the upper limit of the temperature
controller (maximum user selectable water
temperature) by pressing the "Temperature limit"
button.