Installation and Operation Manual of the EUROMATIK.net Page 35 (40)
Storing the settings on the SD card
With this button the configuration settings can be
saved on the Micro SD card in the device.
Loading settings from the SD card
With this button the previously stored configuration
settings can be reloaded from the Micro SD card.
Operating the webserver
After the device has built up a network connection, it can be operated using the embedded Web server.
Communication with the server can be done with any web browser. For access from the Internet, the -
communication-server can be used. Alternatively, the IP address of the device (see Fig. Configuration
menu) can also be entered directly into the browser address bar for local access. If the HMI device is
capable of NetBIOS name resolution (as Windows PCs), the NetBIOS name "EUROMATIK" can be used
instead of the IP-address (http://EUROMATIK).
Homepage
After opening the device in the web browser, the homepage is displayed first:
Icons in the status bar (top)
The Web server is blocked for access from the LAN. It only displays the current state. To operate the device,
the user must first log in by clicking on this icon.
The Web server has been unlocked with service pin for full access.
The solenoid valve for water refill is opened.
A backwash cycle is in progress.
The filtration pump is running.
The solar heating system is operating.
Icons in the control bar (bottom)
Navigation to the system information page