Installation and Operation Manual of the EUROMATIK.net Page 32 (40)
Minimum switching interval for heat pump
The minimum time interval for switching the air heat
pump can be set by pressing the "Minimum air heat
pump time" button. Too frequent switching
operations of the heat pump can be prevented by
doing so.
Priority circuit of the air heat pump
With this button you can select whether the
temperature control for the air heat pump should
take precedence over the programmed filter
periods. Without priority (default setting), the heat
pump can only be switched on within the
programmed filter periods by the temperature
control.
Adjusting the temperature sensors
On this page, the displayed values of the
temperature sensor can be adjusted.
Configuration of the water level control
Select the type of level control system
In this menu you must select the appropriate level
control system for the pool.
Press the "OK" button to save the setting.
The electrical connection of the sensors must be
done according to this setting.
Additional settings can be made after pressing the
“Tools” icon.
Time monitoring of water refill
In this line you can select whether the automatic
refill is terminated after an adjustable maximum
period for safety's sake, to avoid overfilling in case
of malfunctions of the water level sensor.
Maximum duration of water refill
In this line the maximum duration of the water refill
can be adjusted, which passes until the time
monitoring triggers.
Water refill during backwashing
In this line you can select, if
a. water refill is started generally at the
beginning of backwashing, to compensate
for the water loss quickly,
b. water refill is blocked during backwashing,
to avoid a loss in water pressure, or
c. water is refilled automatically, depending
on the current water level.
Minimum switching interval of the solenoid
valve (for pools with skimmer)
The minimum time interval for switching the
solenoid valve can be set by pressing the "Minim.
switch interval refilling" button. Too frequent
switching operations of the valve can be prevented
by doing so.