Installation and Operation Manual of the EUROMATIK.net Page 31 (40)
Minimum switching interval
The minimum time interval for switching the heater
can be set by pressing the "Minimum heating time"
button. Too frequent switching operations of the
heater can be prevented by doing so.
Priority circuit of the heat exchanger
The default factory setting is such that the heater is
switched on only if the filter system is working.
By pressing the "Priority of heating" you can
change the switching priority in such a manner that
the heater is switched on even when the filter pump
is still switched off. In this case, the filter pump is
switched on simultaneously with the heater.
Off delay of the filter pump
By pressing the "Overrun time" button you can set
the time period for which the filter pump continues
to run after the timer has been switched off, in order
to cool down the heater, e.g. heat exchanger
(dissipate the residual energy).
Temperature increase for solar operation
The temperature increase for solar operation
defines how far the pool water is heated over the
setpoint during operation of the solar heating, to
store energy for times without sunlight.
Switch-on temperature difference of solar
heating
In this line you can set, at which temperature
difference between solar absorber and swimming
pool water the solar heating is switched on.
Switch-off temperature difference of solar
heating
In this line you can set, at which temperature
difference between solar absorber and swimming
pool water the solar heating is switched off.
Minimum switching interval for solar heating
The minimum time interval for switching the solar
heating can be set by pressing the "Minimum solar
time" button. Too frequent switching operations of
the solar heating can be prevented by doing so.
Priority circuit of solar heating
With this button you can select whether the solar
temperature control should take precedence over
the programmed filter periods. With activated
priority (default setting), the filter pump can be
switched on beyond the programmed run times by
the temperature control.
Minimum air temperature for heat pump
With this button, the minimum temperature of the
outdoor air for the operation of the air heat pump
can be set, to achieve a sufficient efficiency.