Variables available for communication with the building management system (as of 29/05/2015):
Status text heating system
Status text filtration system
Control of attraction output
0: switch off
1: switch on
i: alter state
Operating mode filter system
„M1“: Pause
„M2“: ECO mode
„M3“: Automatic mode
„M4“: Party mode
0: switch off
1: switch on
i: alter state
0: switch off
1: switch on
i: alter state
0: Stop cover
1: Close cover
2: Open cover
Setpoint water temperature
Temperature decrease for eco mode
Temperature increase for solar mode
Frost protection function
0: switch off
1: switch on
i: alter state
Activation temperature for frost
protection
Water temperature for frost protection
Only if swimming pool / spa
switchover is enabled
'0'=Off
'1'=Heat exchanger
'2'= Solar heating
'3'=Air heat pump
'0': Controller off
'1': Pause
'2': ECO mode
'3': Automatic mode
'4': Party mode
'5': Draining pool