Installation and Operation Manual of the EUROMATIK.net Page 38 (40)
Variables available for communication with the building management system (as of 29/05/2015):
Index
Function
Read/
Write
Format
Value range
Info
0003
LAN-PIN
W
„####“
„0000“ - „9999“
Login
0013
Status text heating system
R
ASCII-Text
0015
Status text filtration system
R
ASCII-Text
0017
Control of attraction output
W
ASCII
'0', '1', 'i'
0: switch off
1: switch on
i: alter state
0019
Operating mode filter system
W
ASCII
„M1“ - „M4“
„M1“: Pause
„M2“: ECO mode
„M3“: Automatic mode
„M4“: Party mode
0025
Manual mode filter pump
W
ASCII
'0', '1', 'i'
0: switch off
1: switch on
i: alter state
0026
Manual mode backwashing
W
ASCII
'0', '1', 'i'
0: switch off
1: switch on
i: alter state
0033
Control of pool cover
W
ASCII
'0', '1', '2'
0: Stop cover
1: Close cover
2: Open cover
0100
Water temperature
R
„##.#“
0101
Solar temperature
R
„##.#“
0102
Air temperature
R
„##.#“
0110
Setpoint water temperature
R/W
„##.#“
„00.1“ - „40.0“
0111
Temperature decrease for eco mode
R/W
„##.#“
„00.0“ - „15.0“
0112
Temperature increase for solar mode
R/W
„##.#“
„00.0“ - „15.0“
0123
Frost protection function
W
ASCII
'0', '1', 'i'
0: switch off
1: switch on
i: alter state
0124
Activation temperature for frost
protection
R/W
„##.#“
-9.9“ - „10.0“
0125
Water temperature for frost protection
R/W
„##.#“
„00.0“ - „20.0“
0160
Setpoint spa temperature
R/W
„##.#“
„00.1“ - „40.0“
Only if swimming pool / spa
switchover is enabled
9000
Collective error message
R
'#'
'0' - '1'
'0'=Off, '1'=On
9013
Status heating system
R
'#'
'0' - '3'
'0'=Off
'1'=Heat exchanger
'2'= Solar heating
'3'=Air heat pump
9017
Status attraction output
R
'#'
'0' - '1'
'0'=Aus, '1'=Ein
9019
Status operating mode
R
'#'
'0' - '5'
'0': Controller off
'1': Pause
'2': ECO mode
'3': Automatic mode
'4': Party mode
'5': Draining pool
9025
Status manual operation
R
'#'
'0' - '1'
'0'=Off, '1'=On
9026
Status backwashing
R
'#'
'0' - '1'
'0'=Off, '1'=On
9123
Status frost protection
R
'#'
'0' - '1'
'0'=Off, '1'=On

Table of Contents