6.Use the Multimeter (Optional)
114
To record the current/voltage measurements in the multimeter, do the
following:
1. Push DMM button on the front panel to enter the multimeter function. Select
Current or Voltage in the bottom menu.
If you want to enter the relative mode, select Configure in the bottom menu,
select Relative in the right menu.
2. Push the Utility button, select Function in the bottom menu, select DAQ in the
left menu.
3. Select Storage in the bottom menu, select Internal or External in the right
menu. If you select External, insert the USB memory device into the front-panel
USB port on your instrument.
4. Select Set in the bottom menu, select Enable in the right menu as ON.
5. Select Interval in the right menu, turn the M knob to set it.
6. Select Duration in the right menu, push it to switch between the time unit, turn
the M knob to set the corresponding value.
7. Select STRT in the bottom menu.
8. When external storage is selected: The instructions will be shown on the
screen. The record file will be named as "Multimeter_Recorder.csv". If a file
with the same name already exists in the USB memory device, it will be
overwritten. (If you want to keep the existing file, back up it to other location in
advance.) Select STRT in the bottom menu to start recording.
9. When the record time gets to the defined duration, the recording will be ended.
If you want to end recording prematurely, select STOP in the bottom menu.
Day H M S
Record time, use the defined
interval as its refresh interval
Function
Menu
Setting
Description
Set
Interval
Set the record interval (0.5s - 10s, step by 0.5s)
Duration
"d h m s" represents day, hour, minute, second.
E.g. "1 02:50:30" represents a day and 2 hours,
50 minutes and 30 seconds.
Press Duration to switch between the time unit,
turn the M knob to set the value. Max duration: 3
days for internal storage, 10 days for external
storage.
Enable
Turn on or off the recorder.
STRT
STOP
Start or stop recording.
Storage
Internal
External
Save to internal storage or USB memory device.
Export
When internal storage is selected, you can export the internal
record file to a USB memory device.