10.Technical Specifications
133
Trigger
Performance Characteristics
Instruction
Trigger level
range
Internal
±5 div from the screen center
EXT
±2V
EXT/5
±10V
Trigger level
Accuracy (typical)
Internal
±0.3 div
EXT
±10mV+6% * value
EXT/5
±50mV+6% * value
Trigger
displacement
According to Record length and time base
Trigger Holdoff
range
100 ns 10 s
50% level setting
(typical)
Input signal frequency ≥ 50 Hz
Edge trigger
slope
Rising, Falling
Video Trigger
Modulation
Support standard NTSC, PAL and
SECAM broadcast systems
Line number
range
1-525 (NTSC) and 1-625
(PAL/SECAM)
Pulse trigger
Trigger condition
Positive pulse:>, ,
Negative pulse:>, ,
Pulse Width range
30 ns to 10 s
Slope Trigger
Trigger condition
Positive pulse:>, ,
Negative pulse:>, ,
Time setting
30 ns to 10 s
Runt Trigger
Polarity
Positive, Negative
Pulse Width
Condition
>, =, <
Pulse Width
Range
30 ns to 10 s
Windows Trigger
Polarity
Positive, Negative
Trigger Position
Enter, Exit, Time
Windows Time
30 ns to 10 s
Timeout Trigger
Edge Type
Rising, Falling
Idle Time
30 ns to 10 s
Nth Edge Trigger
Edge Type
Rising, Falling