4.Advanced User Guidebook
64
Color
Color temperature function uses color-grading to indicate frequency of
occurrence. The hot colors like red/yellow indicate frequently occurring events,
and the colder colors like blue/green indicate rarely occurring events.
Cold Hot
(1) Push the Display button.
(2) Select Persist&Color in the bottom menu.
(3) Select Color in the right menu, choose between ON/OFF.
Figure 4-11 The color temperature function is on
XY Format
This format is only applicable to Channel 1 and Channel 2. After the XY display
format is selected, Channel 1 is displayed in the horizontal axis and Channel 2
in the vertical axis; the oscilloscope is set in the un-triggered sample mode: the
data are displayed as bright spots.
The operations of all control knobs are as follows:
The Horizontal Scale and the Horizontal Position knobs are used to set