SECTION 4 OPERATION
58
4.6.1.1 COPY PROGRAM
COPY PROGRAM is used to copy Program data.
From any METER display (V/I, AMPS or POWER), press the fn key to enter SETUP MODE.
From the SETUP display, press 1 to enter PROGRAM SETUP.
From the PROGRAM SETUP display, press 1 to enter COPY PROGRAM.
COPY PROGRAM: RANGE
SOURCE PROGRAM NUMBER=1 0-103
DESTINATION PROGRAM NUMBER=2 1-99
PRESS STORE TO COPY.
SOURCE PROGRAM NUMBER:
0 will copy the present MANUAL MODE operating parameters.
1-99 are user created programs that may be edited or copied to and from.
Program 100 is a MIL-STD-704D over-voltage transient.
Program 101 is a MIL-STD-704D under-voltage transient.
Program 102 is a MIL-STD-704D over-frequency transient.
Program 103 is a MIL-STD-704D under-frequency transient.
These programs may be copied to any of programs 1 - 99 and executed.
DESTINATION PROGRAM NUMBER:
1-99 are user created programs that may be edited or copied to and from.
NOTE
: You cannot copy to a program that is currently executing.
4.6.1.2 DELETE PROGRAM
DELETE PROGRAM is used to delete programs. This is useful to free up memory.
From any METER display (V/I, AMPS or POWER), press the fn key to enter SETUP MODE.
From the SETUP display, press 1 to enter PROGRAM SETUP.
From the PROGRAM SETUP display, press 2 to enter DELETE PROGRAM.
DELETE PROGRAM: RANGE
PROGRAM TO DELETE=1 1-99
PRESS STORE TO ERASE.
NOTE
: You cannot delete a program that is currently executing.