58
DP-8032/8025
2008Ver. 1.2
(22) Shake the Developer Bottle thoroughly (approx. 30
seconds).
(23) Pour the appropriate developer evenly into the
developer unit. Make sure to empty the bottle.
(24) Close the Developer Cover.
Note:
When reinstalling the Developer Cover, ensure that 2
Magnet Roller Sheets are outside as illustrated.
<Removing the Old OPC Drum>
(25) Remove the OPC Drum Shaft Holder Assembly.
(26) Lift the OPC Drum, holding the right side where the
OPC Drum Shaft Holder Assembly was installed.
Note:
Do not touch the surface of the OPC Drum with bare
hands when removing or reinstalling it. Grease from
fingerprints will affect copy quality. When installing a
new OPC Drum, clean the Bias Charge Roller with a
soft dry cloth.
(27) Remove the Bias Charge Roller (725).
(28) Remove 2 Screws (20).