General Features
Features Guide 113
[Legend]
Error Message
Priority
Alarm LED
(When a problem occurs)
The Alarm light turns red automatically. The corresponding error message is shown on the
display PT, if it is idle, by pressing the red lit Alarm button.
If the red lit Alarm button is pressed again, whether the problem is solved or not, the Alarm
light goes off and the display PT shows the initial display ("Date" and "Time" or "Self-
Extension number").
The Alarm light turns red and the corresponding error message is shown on the display PT
automatically, if it is idle. This situation continues until the problem will be solved.
ERR xyy OGM LOS DISA OGM is lost 2 C
ERR xyy OPX POW OPX power failure 2 C
ERR SMDR Printer is not connected 2 B
ERR xyy DSP1LNK DSP-1linkfailure 2 D
*1
ERR xyy CD FLT Card status fault 2 A
*1
Regarding the T1 card, please refer to Reference Guide for T1 Digital Trunk card.
x: Shelf Number (1-3)
yy: Slot Number (01-14)
z: Error Number
1: Major Error
2: Minor Error
A: LED on PT / Top Shelf / Card...........................OFF ON
B: LED on PT / Top Shelf............................OFF ON
C: LED on PT.............................OFF ON
D: LED on PT / Card.............................OFF ON
E: LED on PT / Top Shelf...........................OFF ON
Error Message List (Priority order)
Error Message Description Priority Alarm LED