Flash Timing - Range
Specifies the
maximum length that a signal sent from an SLT can be for the PBX to recognise it as a hookswitch
flash signal.
Value Range
8 ´ n (n=3–191) ms
Maintenance Console Location
3.4 [1-1] Slot—Card Property - Extension Type
Programming Manual References
None
Feature Guide References
None
DTMF-R STD Detection Time
Specifies the minimum length that a DTMF tone must be for the PBX to recognise it as a DTMF tone.
Value Range
2 ´ n (n=1–31) ms
Maintenance Console Location
3.4 [1-1] Slot—Card Property - Extension Type
Programming Manual References
None
Feature Guide References
None
SLT Power Supply (KX-TDA100/KX-TDA200/KX-TDA600 only)
Selects the voltage that enables an SLT to activate the Message Waiting lamp. This setting is only available