Feature Guide References
1.21.1.2 Calling/Connected Line Identification Presentation (CLIP/COLP)
CO Dial Mode
Selects the type of signal used to dial out to a trunk.
Value Range
DTMF, Pulse
Maintenance Console Location
3.19 [1-1] Slot—Port Property - T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
1.5.4.4 Dial Type Selection
Channel Type
Selects the channel type.
Value Range
Undefined: Not assigned
GCOT: Ground Start Central Office
LCOT: Loop Start Central Office
DDI/DID: Direct Dialling In/Direct Inward Dialling
TIE (E & M): TIE Line
OPX: Off Premise Extension
Maintenance Console Location
3.19 [1-1] Slot—Port Property - T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
1.23.1 T1 Line Service
Trunk Property
Selects the trunk property of the TIE channel.
Value Range
Public: Use the DIL/DDI/DID method to distribute incoming trunk calls.