Pulse Dial—Pulse Minimum MAKE Width
Specifies the minimum length of the make signal in a pulse dial.
Value Range
8 ´ n (n=1–5) ms
Maintenance Console Location
3.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Flash—Flash Detection
Enables the PBX to detect hookswitch flash signals.
Value Range
Disable, Enable
Maintenance Console Location
3.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Flash—Minimum BREAK Width
Specifies the minimum length of the break signal in a flash signal.
Value Range
8 ´ n (n=3–63) ms
Maintenance Console Location
3.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References