5-3. Hysteresis Function
The hysteresis can be switched to one of three settings (small / standard / large) in all sensing modes except for
hysteresis mode.
H-01 (small) H-02 (standard) H-03 (large)
Turn the Jog switch once
toward the direction.
Turn the Jog switch once
toward the
direction.
Press the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
Select the desired hysteresis
by turning the Jog switch.
Press the
MODE key once.
Press the
MODE key once.
Press the
MODE key 5 times.
5If the [Jog switch] is pressed, the current hysteresis level
(red) will be displayed.
* The factory setting is H-02 (standard).
6If the [Jog switch] is turned, hysteresis level (red) will blink on
the digital display.
Select the desired hysteresis level.
7
If the [Jog switch] is pressed, hysteresis level (red) will quickly
blink on the digital display, confirming the hysteresis level.
The digital display will not blink (red) if the setting has not
been changed.
4Turn the [Jog switch] once toward the direction, to enter
the hysteresis setting state.
8If the [MODE key] is pressed once, the amplifier will return to
PRO1 mode.
9Press the [MODE key] once, the amplifier will return to RUN
mode (normal sensing operation).
3Press the [Jog switch] to enter the response time change
state.
2Turn the [Jog switch] once toward the direction, to select
PRO1 mode.
1Press the [MODE key] 5 times to select PRO mode.