9-3. 0-Adjust Setting Function
This function allows for automatic zeroing of the incident light intensity.
* The threshold value is not linked to this function, so that after carrying out zero adjustment, be sure to reset the
threshold value.
Press the
MODE key 5 times.
Turn the Jog switch 5 times
toward the
direction.
Turn the Jog switch once
toward the direction.
Press the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
Press the Jog switch to zero
the incident light intensity.
Turn the
Jog switch.
0-Adjust
ON
0-Adjust
OFF
Press the
MODE key once.
Press the
MODE key once.
The digital display will quickly
blink to confirm the setting.
1Press the [MODE key] 5 times to select PRO mode.
3Press the [Jog switch] to enter the code setting state.
2Turn the [Jog switch] 5 times toward the direction, to
select PRO5 mode.
9If the [MODE key] is pressed once, the amplifier will return to
PRO5 mode.
0Press the [MODE key] once, the amplifier will return to RUN
mode (normal sensing operation).
4Turn the [Jog switch] once toward the direction, to enter
the 0-Adjust setting state.
7When zero adjustment has been completed
n The current incident light intensity will be displayed.
When zero adjustment has not been completed or has been
cancelled
n The amplifier will return to the 0-Adjust setting state.
8If the [Jog switch] is pressed to set the desired incident light
intensity to 0, the digital display (red) will quickly blink,
confirming the zero adjustment.
Note: When zero adjustment is performed with the digital
display showing the 2,000 digits or greater, 1,999
digits or less will not be displayed.
6If the [Jog switch] is turned, 0-Adjust setting (red) will blink
on the digital display.
When setting zero adjustment
n Select SET, then press the [Jog switch].
When not performing zero adjustment or when canceling a
0-Adjust setting that has already been set
n Select OFF, then press the [Jog switch].
5If the [Jog switch] is pressed, the current setting (red) will be
displayed.