4-5. Output Operation Setting Mode
This mode allows the selection of output operation
from either L-ON (Light-ON), or D-ON (Dark-ON).
* Select the output 1 or output 2 beforehand.
ONOFF
OFFON
Threshold
value
Incident light
intensity
Incident light
intensity
Incident light
intensity
Time Time
Output
operation
Output
operation
Output operation
L-ON
D-ON
L-ON
D-ON
L-ON
(Detection-ON)
D-ON
(Detection-OFF)
Output
operation
L-ON
(Detection-ON)
D-ON
(Detection-OFF)
Normal mode
Output
operation
Hysteresis mode
When setting rising
differential mode
When setting trailing
differential mode
ONOFF OFF
OFFON ON
Threshold
value 1
(1_SL)
Threshold
value 2
(2_SL)
Incident
light
intensity
Output
operation
L-ON
D-ON
Window comparator mode
ON level or
OFF level
(2_SL)
OFF level or
ON level
(1_SL)
0 9,999
Press the
MODE key
twice.
Turn the
Jog switch.
Press the
Jog switch.
The digital display will quickly
blink to confirm the setting.
Press the
MODE key
4 times.
The current
setting
9,999
Incident
light
intensity
9,999
1Press the [MODE key] twice to select the ‘output operation
setting mode’.
2The current setting for output operation will be displayed.
* The factory setting is ‘L-ON (Light-ON)’.
5Press the [MODE key] 4 times, the amplifier will return to
‘RUN mode’ (normal sensing operation).
3If the [Jog switch] is turned, the setting for output operation
(‘
’ side
…
‘’ side
…
) will blink on the digital
display.
()
4If the [Jog switch] is pressed, output operation will quickly
blink on the digital display and the selected ‘output operation’
will be confirmed.
The digital display will not blink if the setting has not been
changed.