PRO6 Mode
10
10-1. PRO6 Mode Functions and Settings
PRO6 mode is used to set sensing mode (normal / window comparator / rising differential / trailing differential /
hysteresis) and also to set the shift amounts in window comparator mode and hysteresis mode.
Refer to p. 53 for setting procedure
Output 1 can only be set.
Refer to p. 53 for setting procedure
Output 1 can only be set.
Refer to p. 53 for setting procedure
Output 1 can only be set.
Refer to p. 53 for setting procedure
: Normal Mode
: Hysteresis Mode
:
Window Comparator Mode
:
Rising differential /
Trailing differential Mode
This is a sensing mode for setting a single threshold value and turning output ON
or OFF.
This is a sensing mode for varying the hysteresis in order to cancel out minute
changes in light intensity.
The teaching method can be selected from 1-level teaching, 2-level teaching or
3-level teaching.
This is a sensing mode for setting two threshold values and tuning output ON or
OFF within the set range.
The teaching method can be selected from 1-level teaching, 2-level teaching or
3-level teaching.
This is a mode for canceling out gradual changes in light intensity, so that only
sudden changes are sensed when the incident light intensity increases or
decreases.