6-6. Current Value Storage Function
The current incident light intensity value can be stored.
Press the
MODE key 5 times.
Press the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
Turn the Jog switch twice
toward the
direction.
Turn the Jog switch 4 times
toward the
direction.
Press the
MODE key once.
The digital display will quickly
blink to confirm the setting.
Press the
MODE key once.
5If the [Jog switch] is pressed, the current incident light
intensity (red) will be displayed.
7If the [MODE key] is pressed once, the amplifier will return to
PRO2 mode.
8Press the [MODE key] once, the amplifier will return to RUN
mode (normal sensing operation).
6If the [Jog switch] is pressed, incident light intensity (red) will
quickly blink on the digital display, and the data will be
stored.
4Turn the [Jog switch] 4 times toward the direction, to
enter the current value storage setting state.
3Press the [Jog switch] to enter the display switching state.
2Turn the [Jog switch] twice toward the direction, to
select PRO2 mode.
1Press the [MODE key] 5 times to select PRO mode.
36