Select the desired shift amount
by turning the Jog switch.
The percentage adjustment is variable
from approx. 5 % to 200 %,
in increments of 1 %.
5-4. Shift Function
1 %1 %
Press the
MODE key 5 times.
Turn the Jog switch once
toward the ‘
’ direction.
Turn the Jog switch twice
toward the ‘
’ direction.
Press the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
The digital display will quickly
blink to confirm the setting.
Press the
MODE key once.
Press the
MODE key once.
Shifts the ‘threshold value’ by a certain percentage increment during ‘limit teaching’.
(The percentage adjustment is variable from approx. 5 % to 200 %, in increments of 1 %.)
4Turn the [Jog switch] twice toward the ‘’ direction, to enter
the ‘shift setting’ state.
8If the [MODE key] is pressed once, the amplifier will return to
PRO1 mode’.
9Press the [MODE key] once, the amplifier will return to ‘RUN
mode’ (normal sensing operation).
5If the [Jog switch] is pressed, the current ‘shift amount’ (red)
will be displayed.
* The factory setting is ‘15 %’.
7If the [Jog switch] is pressed, shift amount (red) will quickly
blink on the digital display, confirming the ‘shift amount’
setting.
The digital display will not blink (red) if the setting has not
been changed.
6If the [Jog switch] is turned, shift amount (red) will blink on
the digital display.
Select the desired ‘shift amount’.
If the [Jog switch] is turned once toward the ‘
’ direction,
the shift amount will be
1 %.
If the [Jog switch] is turned once toward the ‘
’ direction,
the shift amount will be
1 %.
The available range for the shift amount:
The percentage adjustment is variable from approx. 5 % to
200 %, in increments of 1 %.
3Press the [Jog switch] to enter the ‘response time change’
state.
2Turn the [Jog switch] once toward the ‘’ direction, to select
‘PRO1 mode’.
1Press the [MODE key] 5 times to select ‘PRO mode’.
27