Settings for NAVI Mode
4-1. NAVI Mode Functions and Settings
4
RUN :
Normal Sensing Operation
TEACH : Teaching Mode
This indicates normal sensing operation. Threshold value (green) and incident light
intensity (red) are displayed in real time. Manual fine adjustment of the ‘threshold
value’ can be performed during normal sensing operation.
The ‘threshold value’ can be set with any of the 3 teaching methods, ‘2-level
teaching’, ‘limit teaching’ and ‘full-auto teaching’.
This mode sets the ‘threshold value’ by utilizing teaching.
When using normal mode
Turn the jog switch to either ‘’ (left) or ‘’ (right) to increase / decrease the
threshold value.
If there are no key operations after a certain period of time or if the MODE key is
pressed (to change to TEACH), the digital display (green) will blink and the setting
will be confirmed.
2-level teaching is a method of setting the threshold value by teaching the
amplifier two different status conditions - sensing object present and sensing
object absent.
The ‘threshold value’ is usually set using this method.
Refer to p. 11 ~ for setting procedure
P. 11
2-level Teaching
Retroreflective type
Retroreflective type
Reflective type
Reflective type
* The incident light intensity display can
display a maximum value of 4,000 in
H-SP (ultra high-speed) mode and
FAST (high-speed) mode. In STD
(standard) mode and U-LG (ultra long-
range) mode, it can display up to a
maximum value of 9,999.
Confirmed
Confirmed
Automatic
AutomaticAutomatic
Turn to '
'
Turn
* When you turn the jog switch to ‘’ or ‘’ in window comparator mode or hysteresis mode, the threshold
value will increase or decrease after the threshold value 1 ‘ ’ or the threshold value 2 ‘ ’ is displayed.
Each time the jog switch is pressed, the display switches between the ‘ ’ threshold value 1 and ‘ ’
threshold value 2.
After ‘ ’ or ‘ ’ is displayed, the respective threshold value will be displayed.
If you turn the jog switch to ‘
’ when the output 1 ‘ ’ is displayed, the following will be displayed.
Change
Turn
Threshold value
Incident light
intensity
Threshold value fine adjustment function
Teaches only the status condition in which no sensing object is within sensing
range (status in which incident light intensity is stable). This method is used to set
a ‘threshold value’ for conducting sensing in the presence of a background, or
when extremely small objects are to be detected.
P. 12
Limit Teaching
Very small object
In [NAVI mode], frequently changed settings can be easily configured.
Settings for four functions can be configured.