10-3. Output 2 Sensing Mode Settings
Output 2 can only be set to normal mode.
Press the MODE key for 2 seconds or more to make the Select 2 indicator illuminate beforehand.
Press the
MODE key 5 times.
Press the
MODE key once.
Press the
MODE key once.
The digital display will quickly
blink to confirm the setting.
Press the
Jog switch.
Press the
Jog switch.
Normal mode Output OFF
Select sensing mode
by turning the Jog switch.
Turn the Jog switch 6 times
toward the
direction.
1Press the [MODE key] 5 times to select PRO mode.
2Turn the [Jog switch] 6 times toward the direction, to
select PRO6 mode.
5If the [Jog switch] is pressed, sensing mode (red) will quickly
blink on the digital display, confirming the sensing mode.
6If the [MODE key] is pressed once, the amplifier will return to
PRO6 mode.
7Press the [MODE key] once, the amplifier will return to RUN
mode (normal sensing operation).
3If the [Jog switch] is pressed, the current setting (red) will be
displayed.
* The factory setting is normal mode.
4Turn the [Jog switch], the sensing mode (red) will blink on
the digital display.
Select from either normal mode or output OFF.
55