EasyManua.ls Logo

Panasonic Minas A4 Series

Panasonic Minas A4 Series
366 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
297
[Supplement]
Supplement
command
2
mode
A
• Read out of Status, Input Signal and Output Signal
Reception data
0
axis
checksum
2A
Error cod
Transmission data
• Meaning of each bit of control mode, status, input signal, output signal and alarm data is as same as that of command
No. 20 (command = 2, mode = 0), 27 (mode = 7) and 28 (mode =8).
bit7
0 : Normal
1 : Error
65
Command error
4
RS485 error
3210
0Dh
axis
control mode
status
input signal L
input signal H
output signal L
output signal H
alarm data L
alarm data H
error code
checksum
2A
command
2
mode
9
• Read out of Present Speed, Torque and Deviation Counter
Reception data
29
Error cod
Transmission data
• Output value of speed and torque are in 16 bit and deviation in 32 bit.
• Unit and sign of the output data is as same as that of command No. 24 (command = 2, mode = 4), 25 (mode = 5) 
and 26 (mode = 6).
bit7
0 : Normal
1 : Error
65
Command error
4
RS485 error
3210
0
axis
checksum
29
9
axis
data L
(speed) H
data L
(torque) H
data L
(deviation) H
error code
checksum