load point relation
P =
3533
L+39
Unit : N (1kgf=9.8N)
L
P
<Note>
When the load point varies, calculate the permissible radial
load, P (N) from the distance of the load point, L (mm) from
the mounting flange based on the formula of the right table,
and make it smaller than the calculated result.
P =
4905
L+59
P =
14945
L+46
P =
19723
L+65.5
P =
37044
L+77
L
L/2
P
A
M
B
Radial load (P) direction
Thrust load (A and B) direction