300
Communication
command
8
mode
1
• Individual Writing of Parameter
Reception data
3
axis
parameter No.
parameter value L
H
checksum
81
Error code
Transmission data
• If the parameter No. is not within the range of 0 x 00 to 0 x 7F, No. error will be returned.
• This command change parameters only temporarily. If you want to write into EEPROM, execute the parameter writing
to EEPROM (mode = 4). 
• Set up parameters not in use to 0 without fail, or it leads to data error. Data error also occurs when the parameter
value exceeds the setup range.
• If the parameter No. is not within the range of 0 x 00 to 0 x 7F, No. error will be returned.
bit7
0 : Normal
1 : Error
6
Data Error
5
Command error
4
RS485 error
Data Error Command error RS485 error
3
No.Error
210
1
axis
error code
checksum
81
command
8
mode
4
• Writing of Parameters to EEPROM
Reception data
0
axis
checksum
84
Error code
Transmission data
• Writes the preset parameters to EEPROM.
• Transmission data will be returned after EEPROM writing completes. It may take max. 5sec for EEPROM writing
(when all parameters have been changed.)
• Data error will occur when writing fails.
• When under-voltage occurs, error code of control LV will be returned instead of executing writing.
Control LV
bit7
0 : Normal
1 : Error
6543210
1
axis
error code
checksum
84
command
8
mode
0
• Individual Read out of Parameter
Reception data
1
axis
parameter No.
checksum
80
Error code
Transmission data
bit7
0 : Normal
1 : Error
65
Command error
4
RS485 error
3
No.Error
210
3
axis
parameter value L
H
error code
checksum
80