Self-
diagnosis
display
Contents Shutdown Display condition Remarks
FE1 Fan error 1: P-UNIT FAN
The fan stops for 5 seconds or longer.
Power unit fan
FE2 Fan error 2: LAMP FAN 1 Lamp fan 1
FE3 Fan error 3: LAMP FAN 2 Lamp fan 2
FE4 Fan error 4: LAMP FAN 3 Lamp fan 3
FE5 Fan error 5: LAMP FAN 4 Lamp fan 4
FE6 Fan error 6: BALLAST1 FAN Ballast fan 1
FE7 Fan error 7: BALLAST3 FAN Ballast fan 3
FE8 Fan error 8: GB-DMD FAN GB-DMD fan
FE9 Fan error 9: EXAUST FAN C Exhaust fan (C)
FF0 Fan error 10: EXAUST FAN L Exhaust fan (L)
FF1 Fan error 11: EXAUST FAN R Exhaust fan (R)
FF2 Fan error 12: R-DMD FAN R-DMD fan
FF3 Fan (Module) error 13: G-LIQUID
COOLING
Liquid cooling pump (G)
FF4 Fan (Module) error 14: B-LIQUID
COOLING
Liquid cooling pump (B)
FF5 Fan error 15: C-PRISM FAN Color prism fan
FF6 Fan error 16: L-PRISM FAN Lamp prism fan
FF7 Fan error 17: BALLAST2 FAN Ballast fan 2
FF8 Fan error 18: BALLAST4 FAN Ballast fan 4
FF9 Fan error 19: G-PRISM FAN G-prism fan
F11 Shutter error Shutter error
F12 Dynamic iris error Dynamic iris error
F13 Air filter unit error Air filter cleaning processing time-out
F21 2.5 V DC error 2.5 V DC error
F22 3.3 V DC error 3.3 V DC error
F23 5.0 V DC error 5.0 V DC error
F41 Lamp 1 memory error *2
Lamp EEPROM is abnormal. LAMP monitor blinks 3 times in
red.
F42 Lamp 2 memory error *2
F43 Lamp 3 memory error *2
F44 Lamp 4 memory error *2
F61 Lamp 1 ballast communication
error
*2
Fails in the communication with the ballast
MPU.
F62 Lamp 2 ballast communication
error
*2
F63 Lamp 3 ballast communication
error
*2
F64 Lamp 4 ballast communication
error
*2
F80 Resize IC setting error No response from the resize IC
F81 FM-R test fail
RDRAM test error
F82 FM-G tset fail
F83 FM-B test fail
F91 FPGA1 configuration error A-P.C.Board is abnormal.
F92 FPGA2/3 configuration error FH-Module is abnormal.
WF-Module is abnormal.
F93 Flash ROM error The circuit around CPU on A-P.C.Board is
abnormal.
F94 RAM error
F95 FPGA expansion error
F96 Lens shift error The circuit for lens position detection is
abnormal.
F97 WF-Module (GEOMETRY)
communication error
No response from the geometry IC Displays in
PT-DZ12000*/DW100* only.
Explanatory notes of shutdown column
Shutdown occurs.
Shutdown does not occur.
*1 Shutdown occurs only when starting. (Shutdown does not occur even if the temperature becomes less than 5°C during normal
operating.)
*2 Shutdown occurs when all lamps cannot be lit.
5.2. Comparison Table of Self-diagnosis Display and Code
Self-diagnosis
display
Code Self-diagnosis
display
Code
U11 00000000 00000000 00000000 00000001 FE4 00000000 00000000 00080000 00000000
16
PT-DZ12000U / PT-DZ12000E / PT-D12000U / PT-D12000E / PT-DW100U / PT-DW100E