Channel Control details Performance Parameter Remark
4 Lens control
Lens
adjustment
(
-
) High
speed
0-31
(
-
) Low
speed
32-63
(
-
) Fine
adjustment
64-95
Adjustment stop 96-127
Lens
adjustment
(+) Fine
adjustment
128-159
(+) Low
speed
160-191
(+) High
speed
192-223
Command performance
execute
224-255
5 Power supply control
Standby 0-63
No operation 64-191
Power on 192-255
6 Light volume adjustment
100 % 0
Can be set in 256 steps
between 100 % and 0 %.
… …
0 % 255
7 Lock
Operation not available 0-127 When “Operation not
available” is set, operations
of all channels become
unacceptable.
Operation available 128-255
8 Fade-in time setting
0.0s 0-15
Operate together with channel
1.
0.5s 16-31
1.0s 32-47
1.5s 48-63
2.0s 64-79
2.5s 80-95
3.0s 96-111
3.5s 112-127
4.0s 128-143
5.0s 144-159
7.0s 160-175
10.0s 176-191
No operation 192-255