Technical information
164 - ENGLISH
Appendix
Channel Control details Performance Parameter Remark
9 Fade-out time setting
0.0s 0-15
Operate together with channel
1.
0.5s 16-31
1.0s 32-47
1.5s 48-63
2.0s 64-79
2.5s 80-95
3.0s 96-111
3.5s 112-127
4.0s 128-143
5.0s 144-159
7.0s 160-175
10.0s 176-191
No operation 192-255
10 Custom masking
OFF 0-31
To use this function, the
optional upgrade kit (Model
No.: ET-UK20) is required.
PC-1 32-63
PC-2 64-95
PC-3 96-127
No operation 128-255
11 GEOMETRY
OFF 0-15
To use PC-1, PC-2, or PC-
3, the optional upgrade kit
(Model No.: ET-UK20) is
required.
KEYSTONE 16-31
CURVED 32-47
PC-1 48-63
PC-2 64-79
PC-3 80-95
CORNER CORRECTION 96-111
No operation 112-255
Note
z
If the projector is operated with the remote control or on the control panel, or by the control command while
controlling the projector by using the Art-Net function, the setting of the DMX controller and the computer
application may be different from the projector status. In that case, set the “Lock” setting of the channel 7 to
“Operation not available” and then reset to “Operation available”. The controls of all channels become reected
to the projector.