9.2. Initialization Pulse Adjust
1. Set Aging pattern 0 (Vset adjustment pattern) by IIC mode.
2. Set the picture adjustment items as follows.
· Picture menu : Standard
· Color temperature : Normal
· Picture : 25
· Aspect : Full
3. Connect Oscilloscope to TPSC1 and adjust VR6601 for 190V ± 7V.
4. Connect Oscilloscope to TPSC1 (T2) and adjust VR6602 for 165 ± 10µ Sec.
Test point Volume Level
TPSC1 (SC) VR6601 (SC) 190V ± 7V
T2 TPSC1 (SC) VR6602 (SC) 165 ± 10µ Sec