Digiplex/DigiplexNE LCD Keypad 17n
4.8 MUTING
SECTION [004]: OPTION [1]
The keypad can be programmed not to emit audible sounds,
including Chimed zones. During Muting, the keypad will only emit the
Confirmation Beep, Rejection Beep, and beep when a button is
pressed.
Option [1] OFF= Audible sounds (default).
Option [1] ON = Mute.
4.9 BEEP ON EXIT DELAY
SECTION [004]: OPTION [2]
The keypad can beep once every second during the Exit Delay
Timer. During the final 10 seconds, it will beep more rapidly to
provide a final warning before the area is armed.
Option [2] OFF= Exit Delay beep disabled.
Option [2] ON = Exit Delay beep enabled (default).
4.10 CHIME ON ZONE CLOSURE
SECTION [004]: OPTION [4]
During the Chime Zone Time Period that the user sets, the keypad
can emit an intermittent beep whenever a zone with the Chime
feature enabled closes (see Digiplex or DigiplexNE User Manual for
details on Chime Zones). If the user does not set the Chime Zone
Time Period and this option is enabled, the Chime Zones will always
beep upon closure.
Option [4] OFF= Chime on Zone Closure disabled (default).
Option [4] ON = Chime on Zone Closure enabled.