Digiplex/DigiplexNE LCD Keypad 29n
6.4.2 DOOR LEFT OPEN INTERVAL BEFORE ACCESS ALARM
SECTION [010]
The Door Left Open Interval is the time that a door can remain
open after an Access Granted or a Request for Exit without
generating an Access Alarm. Enter any value between 001
and 255 to determine the number of seconds the door may
remain open before the Access Alarm is triggered. Default =
60 seconds.
6.4.3 DOOR LEFT OPEN PRE-ALARM
SECTION [004]: OPTION [3]
If an Access Control door is programmed with a Door Left
Open Interval (see section 6.4.2 above), the Pre-Alarm will
cause the reader to beep a certain time before the end of the
Door Left Open Interval to alert users that the Access Control
door was left open and will generate an Access Alarm if it is
not closed. The Pre-Alarm beeps slower than the Door Left
Open Alarm (about twice every second). Program the Pre-
Alarm timer in section [011].
Option [3] OFF= The Pre-Alarm will not be generated.
Option [3] ON = Pre-Alarm is enabled (default).
6.4.4 DOOR LEFT OPEN PRE-ALARM TIMER
SECTION [011]
This timer will trigger the Door Left Open Pre-Alarm before the
end of the Door Left Open Interval (see section 6.4.3 above).
For example, if 60 seconds is programmed in section [010] and
15 seconds is programmed in section [011], then 60 minus 15 is
45. Therefore, the reader will start beeping after the door has
been open for 45 seconds. Enter any value between 001 and
255 to determine the seconds before the expiry of the Door Left
Open Interval that the reader will beep. Default = 15 seconds.

Table of Contents

Other manuals for Paradox DGP2-641

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox DGP2-641 and is the answer not in the manual?

Paradox DGP2-641 Specifications

General IconGeneral
BrandParadox
ModelDGP2-641
CategorySecurity System
LanguageEnglish

Related product manuals