Digiplex/DigiplexNE LCD Keypad 25n
6.2.4 READER'S LED OPTIONS UPON ACCESS GRANTED
SECTION [006]: OPTION [7]
When the Access Control card is presented to the reader, the
reader's LED can be programmed to turn green during the
door’s unlocked period (or until the door closes) or extinguish
briefly to indicate that the door is unlocked.
Option [7] OFF= The reader's red LED will extinguish briefly.
Option [7] ON = The reader's red LED will turn green (default).
6.3 DOOR LOCK OPTIONS
The Door Lock Options allow you to program the door lock to suit its
environment or security requirements.
6.3.1 UNLOCK ON REX (REQUEST FOR EXIT)
SECTION [006]: OPTION [8]
When the REX device detects movement, it can permit
passage with or without turning the door handle. If this option
is on, the door is unlocked when the REX device detects
movement and users on either side of the door will be able to
open the door. If this option is off, the door will unlock once the
handle is turned only on the REX device’s side.
Option [8] OFF= Unlock on REX disabled (default).
Option [8] ON = Unlock on REX enabled.
6.3.2 DOOR UNLOCKED PERIOD
SECTION [008]
The Door Unlocked Period is the time the door can remain
unlatched after access is granted or after a Request for Exit is
received. Enter any value between 001 and 255 to determine
the seconds the door can remain unlatched. Default = 5
seconds.