EasyManua.ls Logo

Penguin Computing Relion 1900e - Table 59. Node Manager Health Event

Penguin Computing Relion 1900e
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Relion 1900e/2900e Manual
133 Revision 1.3
Table 59. Node Manager Health Event
Node Manager Health
Event
Request
Byte 1
- EvMRev
=04h (IPMI2.0 format)
Byte 2
Sensor Type
=DCh (OEM)
Byte 3
Sensor Number
(Node Manager Health sensor)
Byte 4
Event Dir | Event Type
[0:6]
Event Type
= 73h (OEM)
[7]
Event Dir
=0 Assertion Event
Byte 5
Event Data 1
[0:3]
Health Event Type
=02h
Sensor Node Manager
[4:5]=10b
OEM code in byte 3
[6:7]=10b
OEM code in byte 2
Byte 6
Event Data 2
[0:3]
Domain Id (Currently, supports only one domain,
Domain 0)
[4:7]
Error type
=0
-9 - Reserved
=10
Policy Misconfiguration
=11
Power Sensor Reading Failure
=12
Inlet Temperature Reading Failure
=13
Host Communication error
=14
Real-time clock synchronization failure
=15
Reserved
Byte 7
Event Data 3
if error indication = 10 <PolicyId>
if error indication = 11 <PowerSensorAddress>
if error indication = 12 <Inlet
SensorAddress>
Otherwise set to 0.

Table of Contents