Relion 1900e/2900e Manual
Revision 1.0 74
Multiple stepwise linear and clamp controls can be defined for each fan domain and used simultaneously.
For each domain, the BMC uses the maximum of the domain’s stepwise linear control contributions and the
sum of the domain’s clamp control contributions to compute the domain’s PWM value, except that a
stepwise linear instance can be configured to provide the domain maximum.
Hysteresis can be specified to minimize fan speed oscillation and to smooth fan speed transitions. If a
Tcontrol SDR record does not contain a hysteresis definition, for example, an SDR adhering to a legacy
format, the BMC assumes a hysteresis value of zero.
7.3.14.5 Thermal and Acoustic Management
This feature refers to enhanced fan management to keep the system optimally cooled while reducing the
amount of noise generated by the system fans. Aggressive acoustics standards might require a trade-off
between fan speed and system performance parameters that contribute to the cooling requirements,
primarily memory bandwidth. The BIOS, BMC, and SDRs work together to provide control over how this
trade-off is determined.
This
capability requires the BMC to access temperature sensors on the individual memory DIMMs.
Additionally, closed-loop thermal throttling is only supported with DIMMs with temperature sensors.
7.3.14.6 Thermal Sensor Input to Fan Speed Control
The BMC uses various IPMI sensors as input to the fan speed control. Some of the sensors are IPMI models
of actual physical sensors whereas some are “virtual” sensors whose values are derived from physical
sensors using calculations and/or tabular information.
The f
ollowing IPMI thermal sensors are used as input to fan speed control:
Front Panel Temperature Sensor
1
CPU
Margin Sensors
2,4,5
DIM
M Thermal Margin Sensors
2,4
Exit
Air Temperature Sensor
1, 7, 9
PCH T
emperature Sensor
3,5
On-boa
rd Ethernet Controller Temperature Sensors
3, 5
Add-In In
tel SAS Module Temperature Sensors
3, 5
PSU Th
ermal Sensor
3, 8
CPU V
R Temperature Sensors
3, 6
DIM
M VR Temperature Sensors
3, 6
BMC
Temperature Sensor
3, 6
Glob
al Aggregate Thermal Margin Sensors
7
Hot
Swap Backplane Temperature Sensors
I/O Module Temperature Sensor (With option installed)
Intel
®
SAS Module (With option installed)
Riser Card Temperature Sensors
Intel
®
Xeon Phi™ coprocessor (With option installed)
Note
s:
1. For fan speed control in Intel chassis
2. Temperature margin from throttling threshold
3. Absolute temperature
4. PECI value or margin value
5. On-die sensor

Table of Contents

Related product manuals