Installer manual Fleck 5600 SXT - Description
Ref. MKT-IM-013 / E - 23.09.2020 15 / 104
3 Description
3.1 Technical specifications
Design specifications/ratings
Valve body Fiber-reinforced polymer
Rubber components EP or EPDM
Valve material certification DM174, ACS, CE
Weight (valve with controller) 2kg (max)
Recommended operating pressure 1.4 - 8.6bar
Maximum inlet pressure 8.6bar
Hydrostatic test pressure 20bar
Water temperature std 1 - 43°C
Ambient temperature 5 -40°C
Flow rates (3.5bar inlet - valve only)
Continuous service flow (Δp=1bar) 4.5m
3
/h
Peak service flow (Δp=1.8bar) 5.9m
3
/h
Cv* 5.2gpm
Kv* 4.5m
3
/h
Maximum backwash flow
(Δp=1.8bar)
1.6m
3
/h
*Cv: Flow rate in gpm across the valve at a pressure drop of 1 psi at 60°F.
*Kv: Flow rate in m
3
/h across the valve at a pressure drop of 1 bar at 16°C.
Valve connections
Tank top mounted adapter 2½”- 8 NPSM
Inlet/Outlet ¾" or 1"
Riser tube 26.7mm O.D., 1.05"tube
Drain line ½"O.D.
Brine line (1650) ⅜"
Electrical
Power supply 230 AC, 50/60Hz, 15VA
Transformer output voltage 24VAC, 10VA max.
Motor input voltage. 24VAC
Controller input voltage 24VAC
Controller max. power consumption 5W
Protection rating IP22
Transient overvoltages within the limits of category II