Installer Manual 255/LOGIX 742-762-764 - Programming
Ref. MKT-IM-021 / A - 20.02.2019 47 / 92
6.3.1.5 Regeneration time
Set the time when regeneration will take place.
6.3.1.6 Days override (762 controller only)
Set the number of days for calendar override.
6.3.1.7 Days between regeneration (742 controller only)
Set the number of days between regeneration.
6.3.1.8 Day of week regeneration (742 controller only)
Note
This parameter is available only if days between regeneration is set to "0".
Select the days when regeneration will take place.
A Press .
→ Regeneration time flashes.
B Adjust displayed time with and .
C Default setting: 2:00am.
D Press to validate the selection and advance to the next
parameter.
A Press .
→ Number of days flashes.
B Adjust displayed number with and .
→ Default setting: 0 day (disabled).
→ Days can be adjusted from ½ (.5) to 99 days.
C Press to validate the selection and advance to the next
parameter.
A Press .
→ Number of days flashes.
B Adjust displayed number with and .
→ Set to 0 to program as a day of week timer.
→ Days can be adjusted from ½ (.5) to 99 days.
C Press to validate the selection and advance to the next
parameter.
A Press .
→ Arrow flashes.
B Activate/deactivate the day indicated by the flashing arrow with
and .
→ A flag appears below the day when this is activated.
C Press to validate and repeat for each day.