Installer Manual 255/LOGIX 742-762-764 - Programming
48 / 92 Ref. MKT-IM-021 / A - 20.02.2019
6.3.1.9 Amount of salt used per regeneration
Set desired salt amount in g/L.
6.3.1.10 Estimated system capacity
Note
The system capacity is displayed in kilograms equivalent CaCO
3
of hardness removed
before a regeneration is necessary.
Note
The system capacity is calculated by the Logix software, using the resin volume and salt
dosage.
Note
This parameter can be overridden for 762 controller and is view only for 742 controller.
Set the estimated system capacity on the controller.
Note
If using the 742 controller, programming is complete. The controller will return you to the
normal operation mode.
6.3.1.11 Hardness (762 controller only)
Set inlet water hardness at installation site.
A Press .
→ Salt amount flashes.
B Adjust displayed salt amount with and .
C Press to validate the selection and advance to the next
parameter.
A Press .
→ capacity flashes.
B Adjust displayed capacity with and .
C Press to validate the selection and advance to the next
parameter.
A Press .
→ Hardness flashes.
B Adjust displayed hardness with and .
C Press to validate the selection.
→ Basic programming is now complete. The controller will
return you to the normal operation mode.

Table of Contents

Other manuals for Pentair Logix 762

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair Logix 762 and is the answer not in the manual?

Pentair Logix 762 Specifications

General IconGeneral
BrandPentair
ModelLogix 762
CategoryControl Unit
LanguageEnglish

Related product manuals