Table of Contents

Other manuals for Permalert PAL-AT AT30C

Question and Answer IconNeed help?

Do you have a question about the Permalert PAL-AT AT30C and is the answer not in the manual?

Permalert PAL-AT AT30C Specifications

General IconGeneral
Sensor TypeElectrochemical
Gas DetectedHydrogen Sulfide (H2S)
Alarm TypeAudible and Visual
Ingress ProtectionIP66
Accuracy (H2S)±5% of reading
Visual AlarmLED
Operating Temperature-20°C to 50°C
Operating Humidity15% to 90% RH (non-condensing)
Battery Life2 years
CertificationsATEX, IECEx, UL
Temperature Range-20°C to 50°C
Audible Alarm90 dB at 1 foot
Accuracy (Temperature)±0.5°C

Summary

Introduction to PAL-AT System

Theory of Operation

Explains the pulsed cable-radar technology used for leak detection and system functionality.

Start Up and Installation

Covers initial system startup, installation instructions, and basic setup procedures.

Operating the PAL-AT System

Setup Procedures

Guides through configuring cables, probes, and system parameters for operation.

Reference Maps Management

Details the creation, rules, and management of reference maps for accurate leak detection.

Verify and Monitor Cable Status

Explains how to turn automatic monitoring on/off and check cable status against reference maps.

System Monitoring Functions

Describes the system's continuous monitoring mode, fault reporting, and alarm management.

Password Security and Access

Manages user access levels and security passwords for system functions and configuration.

Communications Options

Explains various communication protocols and software for data exchange with the PAL-AT.

Responding to Alarm Conditions

Alarm Response Decisions

Provides guidance on making alarm response decisions based on leak location and severity.

Types of Alarm Conditions

Describes different alarm types like Fault, Break, Short, Leak, and Probe activation.

Leak Analysis Procedures

Offers procedures for analyzing and locating leaks in various application environments.

Tests and Maintenance Procedures

Selecting Test Mode

Instructions for enabling/disabling test mode to prevent false map creation during testing.

Conducting Alarm Tests

Describes how to periodically test the alarm circuitry for proper function.

USB Port Functions

Details using the USB port for firmware upgrades and data logging.

Troubleshooting PAL-AT Systems

Initial Power-Up Checks

Essential checks to perform before powering up the PAL-AT system.

Understanding Diagnostic LEDs

Explains the status indicated by various LEDs on the system board for diagnostics.

Cable Connector Testing

Procedures for testing cable continuity and insulation to ensure proper connections.

Troubleshooting Guide

A comprehensive guide to common problems and their solutions for PAL-AT systems.

Appendix A: Output Relay System

Output Relay System Installation

Provides instructions for installing the output relay system components and connections.

PAL-AT Control of Output Relays

Describes how the PAL-AT system manages and assigns output relays based on detected events.

Product Warranty Information